Tysen-kld

STATIC PFC MODULES

Compact Modular StructureExcellent Heat Dissipation & Easy Installation

BKS+M series compensation modules forms a filter circuit by low-voltage capacitors, filter reactors, contactors, fuses and connecting wires, used for reactive power compensation.Module has excellent heat dissipation performance, easy installation.

Energy Saving

BKS+M static compensation module is effective for solving the reactive impact generated by various loads.It makes power factor enhance obviously, and is a kind of new-energy saving device with remarkable economic benefit.

Solution Characteristics

  • Compact structure, small floor area
  • Easy installation and maintenance
  • Good heat dissipation performance
  • Easy to assemble, disassemble and maintain
  • High degree of operation security
  • Low capacitor loss, safe and stable
  • Fast switching capacitor bank number
  • Conform to IEC, IEEE , GB standard, etc

Application Areas

The static compensation modules is suitable for occasions with not frequently changing loads. It has great demand in metallurgy, electrification railway, coal and other areas.It is effective for solving the reactive impact, makes power factor enhance obviously, and is a kind of saving device with remarkable economic benefit.

  • The module consists with reactance rate of 7%, tuning frequency of 189Hz, can effectively suppress 5th or above harmonic pollution.
  • The module consists with reactance rate of 14%, tuning frequency of 134Hz, can effectively suppress 3th or above harmonic pollution.

Solution Selections

Reactance Rate 7%, Capacitor Un=480V, Over-current Capability: 2.0In

Model Selection Table I for BKS+M Series Compensation Components (with 25kvar as the minimum switching unit)

Compensation
Capacity (kvar)
Steps Model Reactance Rate Configuration System Voltage
50 3 KLD-BKS7-50/3+M-400V 7% 12.5kvar×2+25kvar×1 400
75 4 KLD-BKS7-75/4+M-400V 7% 12.5kvar×2+25kvar×2 400
100 3 KLD-BKS7-100/3+M-400V 7% 25kvar×2+50kvar×1 400
125 3 KLD-BKS7-125/3+M-400V 7% 25kvar×1+50kvar×2 400
150 4 KLD-BKS7-150/4+M-400V 7% 25kvar×2+50kvar×2 400
175 4 KLD-BKS7-175/4+M-400V 7% 25kvar×1+50kvar×3 400
200 5 KLD-BKS7-200/5+M-400V 7% 25kvar×2+50kvar×3 400
225 5 KLD-BKS7-225/5+M-400V 7% 25kvar×1+50kvar×4 400
250 6 KLD-BKS7-250/6+M-400V 7% 25kvar×2+50kvar×4 400
275 6 KLD-BKS7-250/6+M-400V 7% 25kvar×1+50kvar×5 400
300 6 KLD-BKS7-300/6+M-400V 7% 50kvar×6 400
325 7 KLD-BKS7-325/7+M-400V 7% 25kvar×1+50kvar×6 400
350 7 KLD-BKS7-350/7+M-400V 7% 50kvar×7 400

Reactance Rate 14%, Capacitor Un=525V, Over-current Capability: 2.0In

Model Selection Table II for BKS+M Series Compensation Components (with 25kvar as the minimum switching unit)

Compensation
Capacity (kvar)
Steps Model Reactance Rate Configuration System Voltage
50 3 KLD-BKS14-50/3+M-400V 14% 12.5kvar×2+25kvar×1 400
75 4 KLD-BKS14-75/4+M-400V 14% 12.5kvar×2+25kvar×2 400
100 3 KLD-BKS14-100/3+M-400V 14% 25kvar×2+50kvar×1 400
125 3 KLD-BKS14-125/3+M-400V 14% 25kvar×1+50kvar×2 400
150 4 KLD-BKS14-150/4+M-400V 14% 25kvar×2+50kvar×2 400
175 4 KLD-BKS14-175/4+M-400V 14% 25kvar×1+50kvar×3 400
200 5 KLD-BKS14-200/5+M-400V 14% 25kvar×2+50kvar×3 400
225 5 KLD-BKS14-225/5+M-400V 14% 25kvar×1+50kvar×4 400
250 6 KLD-BKS14-250/6+M-400V 14% 25kvar×2+50kvar×4 400
275 6 KLD-BKS14-250/6+M-400V 14% 25kvar×1+50kvar×5 400
300 6 KLD-BKS14-300/6+M-400V 14% 50kvar×6 400
325 7 KLD-BKS14-325/7+M-400V 14% 25kvar×1+50kvar×6 400
350 7 KLD-BKS14-350/7+M-400V 14% 50kvar×7 400

For more detailed technical information, please call Tysen-kld.

Tysen-kld